The P-10 digital motor load monitor uses a unique and patented method of measuring the torque of a pump's drive motor. By monitoring the "normal" load level any deviation from this range changes the state of the internal relay activating a red LED alarm light. The output relay will shut down the pump, activate additional alarm and / or communicate with other equipment in the process. Designed for use in conjunction with a motor starter, the P-10 protector will monitor motor underload OR overload. In pumping applications, conditions such as dry run, cavitation, damaged impeller, closed valves or blockages will create an "abnormal" underload condition, which the P-10 will detect and subsequently shut down the pump and provide communication to users and / or processes.

Performance:
.4A -50A
Features:
shuts down pump in the event of:
- DRY RUN
- CAVITATION
- DAMAGED IMPELLER
- CLOSED INLET VALVE
- CLOSED OUTLET VALVE
- BLOCKAGES
of 1
Action | Sku | Price | Description | Material | Electric Data |
---|---|---|---|---|---|
99-1172 | $915.00 | Current Transducer | Unspecified | 25.1-50FLA |